Comprasion table of MO-05M versions

Download comparison table of versions in PDF format
Product variant 1 2 3 4 и 4WS 5 и 5WS 6 и 6WS 7 и 7WS 8 и 8WS
Error type Reduced Reduced Reduced Reduced Reduced Reduced Relative Relative
Indicator type LED display LED display LED display LCD display LCD display LCD display LCD display LCD display
Measurement units Pa; kPa; mmHg. or kPa; MPa; kgf/sm2 (depends from manometer’s upper limit of measurement) Pa, kPa, MPa, kgf/sm2, mBar, Bar, mmHg., psi (depends from manometer’s upper limit of measurement and error)
Type of MH Removable MH (Possibility to order MH as SMI) Non-removable MH "Snail" type Non-removable MH Non-removable MH "Snail" type Removable MH (Possibility to order unlimited quantities MH for one terminal) Non-removable MH Non-removable MH Removable MH (Possibility to order unlimited quantities MH for one terminal)
Number of subranges 5 or 6 5 5 or 6 5 5 or 6 5 or 6 1 1
Upper limit of measurement (measurement subranges) ±40 kPa (±40; ±25; ±16; ±10; ±6)
0,25 MPa (0,25; 0,16; 0,1; 0,06; 0,04; - 0,1)
-0,1 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4; - 0,1)
0 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4)
16 MPa (16; 10; 6; 4; 2,5)
60 MPa (60; 40; 25; 16; 10)
100 MPa (100; 70; 60; 40; 25)
±10 kPa (±10; ±4; ±1; ±0,6; ±0,4) ±2 kPa (±2; ±1,6; ±1; ±0,6; ±0,4)
±6 kPa (±6; ±4; ±2,5; ±1,6; ±1)
±40 kPa (±40; ±25; ±16; ±10; ±6)
0 ÷ 40 kPa (40; 25; 16; 10; 6)
0,25 MPa (0,25; 0,16; 0,1; 0,06; 0,04; - 0,1)
-0,1 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4; - 0,1)
0 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4)
16 MPa (16; 10; 6; 4; 2,5)
60 MPa (60; 40; 25; 16; 10)
100 MPa (100; 70; 60; 40; 25)
±10 kPa (±10; ±4; ±1; ±0,6; ±0,4) ±40 kPa (±40; ±25; ±16; ±10; ±6)
0,25 MPa (0,25; 0,16; 0,1; 0,06; 0,04; - 0,1)
-0,1 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4; - 0,1)
0 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4)
16 MPa (16; 10; 6; 4; 2,5)
60 MPa (60; 40; 25; 16; 10)
100 MPa (100; 70; 60; 40; 25)
±2 kPa (±2; ±1,6; ±1; ±0,6; ±0,4)
±6 kPa (±6; ±4; ±2,5; ±1,6; ±1)
±40 kPa (±40; ±25; ±16; ±10; ±6)
0 ÷ 40 kPa (40; 25; 16; 10; 6)
0,25 MPa (0,25; 0,16; 0,1; 0,06; 0,04; - 0,1)
-0,1 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4; - 0,1)
0 ÷ 2,5 MPa (2,5; 1,6; 1; 0,6; 0,4)
16 MPa (16; 10; 6; 4; 2,5)
60 MPa (60; 40; 25; 16; 10)
100 MPa (100; 70; 60; 40; 25)
-0,1 ÷ 0,25 MPa
0 ÷ 2,5 MPa
-0,1 ÷ 2,5 MPa
0 ÷ 16 MPa
0 ÷ 60 MPa
0 ÷ 100 MPa
-0,1 ÷ 0,25 MPa
0 ÷ 2,5 MPa
-0,1 ÷ 2,5 MPa
0 ÷ 16 MPa
0 ÷ 60 MPa
0 ÷ 100 MPa
Permissible error limit, % 0,1; 0,15; 0,25; 0,4 0,05; 0,1; 0,15; 0,25; 0,4 0,02; 0,025; 0,05; 0,1; 0,15; 0,25; 0,4 0,05; 0,1; 0,15; 0,25; 0,4 0,1; 0,15; 0,25; 0,4 0,02; 0,025; 0,05; 0,1; 0,15; 0,25; 0,4 0,02; 0,025; 0,05; 0,1; 0,15; 0,25; 0,4 0,1; 0,15; 0,25; 0,4
Climatic version UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
UHL3.1 (+18 ÷ +28 ºС) - Х0 UHL3.1 (+18 ÷ +28 ºС) - Х0
UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
UHL3.1 (+18 ÷ +28 ºС) - Х0 UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
UHL3.1 (+18 ÷ +28 ºС) - Х0
UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
UHL3.1 (+18 ÷ +28 ºС) - Х0
UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
UHL3.1 (+5 ÷ +50 ºС) - Х1
UHL3.1 (-10 ÷ +50 ºС) - Х2
UHL3.1 (-30 ÷ +70 ºС) - Х3
Additional error due to temperature deviation Manometers, produced with climatic versions UHL3.1 (+18 ÷ +28 ºС) - Х0 и UHL3.1 (+5 ÷ +50 ºС) - Х1, don’t have additional error.
Manometers, produced with climatic versions UHL3.1 (-10 ÷ +50 ºС) - Х2 и UHL3.1 (-30 ÷ +70 ºС) - Х3, have additional error, caused by a deviation of the ambient temperature from the temperature range from +21 to +25 °C in the operating temperature range of the manometer - 0.8γ for every 10 °C
Calibration interval 1 year - for manometers with permissible error limits ±0.02; ±0.025; ±0.05% and for versions 4MS, 5MS, 6MS, 7MS, 8MS; 2 years - for manometers with permissible error limits ±0.1; ±0.15; ±0.25 and ±0.4%
Weather station (WS) Not installed Additional option (signed as "WS" in product name)
Weather station measurement range - atmosphere pressure: from 600 to 800 mmHg
- relative humidity: from 20 to 90 %
- ambient air temperature: from +5 to +50 °С
Limits of permissible absolute error in measurements of weather station parameters - atmosphere pressure: ±1,5 mmHg
- relative humidity: ±7 %
- ambient air temperature: ±1 °С
Adjusting values Possible on each subrange using a special IR remote control
Switching between measurement subranges and different modes - using control buttons on the front panel;
- on a PC using special software (available on the official website)
Variants General industrial;
oxygen (depends by upper limit of measurement and manometer error)
Measurement substance depends by upper limit of measurement and variant: air, non-aggressive gases, water, oil, alcohol
Dust and moisture protection IP65
Mean time between failures 150000 h.
Average service life 12 years
Warranty period 12 months from the date of sale
Power supply - three lithium AA power supplies;
- external power supply with mini USB/Type-C connector (additional option)
Continuous operation time on lithium cells - Manometers with LED display for at least 320 h. (except for manometers with upper limit of measurement ±6 kPa, ±2 kPa, where no less than 160h.);
- Manometers with LCD display with no less than 700 h. (except for manometers with upper limit of measurement ±6 kPa, ±2 kPa, where no less than 350h.)
- three AA lithium batteries (1.5V), charger, Type-C2 cable
Communication protocol USB (virtual COM-port)
Manufacturing material - shell: aluminum alloy D16T (except for manometers with MH "Snail" type)
- fitting: stainless steel AISI 304 (except for manometers with MH "Snail" type)
threaded connection M20х1,5 Herringbone connection М20х1,5 Herringbone connection M20х1,5 M20х1,5 M20х1,5 M20х1,5
Overall dimensions (width×length×height), mm, no more than 108×49×220 250×250×190 108×49×220 250×250×190 108×49×220 108×49×220 108×49×220 108×49×220
Weight, kg, no more than 0,8 6,2 0,8 6,2 0,8 0,8 0,8 0,8